Home > Ibm Error > Iec143i 213-04

Iec143i 213-04

Contents

QSAM FILE STATUS 92 Probable user error. Check the JCL for any inconsistencies in the label, the vol=ser, or the dsn. 2. Ask the operator to reply 'U' or specify another volume serial. Tape positioning error.

S837 Tape volume error occurring only for tape datasets. S213 - DSCB NOT FOUND; I/O ERROR IN READING OR WRITING DSCB. ***IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE*** ***S213 OPERAND FOR MORE SPECIFIC INFORMATION: H The EZTVFM file is not large enough for the report being generated. 2. S806-08 An uncorrectable input/output error occurred when the BLDL control program routine attempted to search the directory of the library that contained the program whose entry point was specified. http://www.ibm.com/support/docview.wss?uid=isg3T1010622

Iec143i 213-04

During the execution of open it was detected that the blocksize was larger than the primary extent. S317 - 08 - THE DSCB READ DURING EXECUTION OF A BSAM CLOSE TYPE=T MACRO INSTRUCTION DID NOT HAVE THE EXPECTED FORMAT-1 OR FORMAT-4 FORMAT ID. NOTE - THIS ERROR IS DETECTED AND FIXED IN FORTRAN S0CD - EXPONENT UNDERFLOW EXCEPTION A FLOATING POINT NUMBER IS SMALLER THAN THE MINIMUM. This is likely not a programmer error.

  • SA13 An error occurred in opening a tape data set. 1.
  • See message TEC155I.
  • S002 - 08 - AN INVALID RECORD WAS ENCOUNTERED ON A PUT OR WRITE OPERATION.
  • S305 The error occurred during execution of a FREEMAIN macro: The specified subpool could not be found.
  • THE PROGRAM RUNNING AT THE TIME THE OPERATOR PRESSED THE RESTART BUTTON WAS SENT THROUGH ABEND PROCESSING BECAUSE THE OPERATOR DETERMINED IT WAS IN A NONCANCELABLE LOOP OR WAIT STATE.
  • A write to the file was attempted when it was not opened for output. 3.
  • A division gave a quotient which was too large for the program defined field.
  • If you would prefer to download this information as an Adobe® Portable Document File, use this link: http://www.jaymoseley.com/hercules/downloads/pdf/sabends.pdf.
  • S002 - 9C - INCORRECT UPDATE WRITE DETECTED.

The DCB is not open or is invalid. 04An I/O error was encountered while obtaining the directory information. 113 A DCB was used to OPEN a VSAM file. S0CA Decimal overflow exception. BUFFER CONTROL BLOCK; IE. Be sure that the concatenated partitioned data set is being opened properly.

S0D9 - A PROGRAM CHECK, INTERRUPTION CODE 38 (PAGE FAULT ASSIST ERROR) HAS OCCURRED. Iec143i 213-30 S706-04 Improper program linkage (NON-IMS pgm linked used LNKTESTI Clist) S713 Tried to write on a dataset whose data protection had not expired. S002 DCB had the wrong block size, IEHMOVE-attempt to rename dataset when new name already exists, wrong RECORD format specified in JCL. An error occurred because the tape had nonstandard labels or none at all.

S002 - 60 - NON-ZERO KEYLENGTH SPECIFIED FOR OUTPUT PDSE MEMBER. Need more core in region. S137-14 An I/O error occurred reading header labels for a dataset opened for input or inout, or reading the trailer label for a dataset opened for RDBACK. S205 - 00 - (00 IS THE ONLY POSSIBLE RETURN CODE ASSOCIATED WITH S205) GETMAIN ERROR.

Iec143i 213-30

S0C4 Protection exception - virtual address could not be translated into a real address; Possible subscript error or bad parms; Variable length record larger than maximum target field size; missing or SPECIFY A JFCB EXIT, SUPPLY THE JFCB. Iec143i 213-04 Try a larger REGION parm on the JOB CARD. S213 Abend In Mainframe See message TEC024I.

The select clause in the file-control paragraph did not specify an index sequential data set, when in fact the data set was indexed sequential. 5. The mass storage system did not mount the requested volume. S0E0 - 31 - AN UNSTACKING INTRUCTION WAS ISSUED WHEN THE LINKAGE STACK HAS NO STACK ENTRIES. S337 The error occurred when the end of a data set was reached. Abend S213 Reason 30

S16E - 1C - DEBAMTYP OR DEBTBLOF = 0 FOR TYPE = ADD. Previous dataset on this tape protected, new dataset is not protected. S013-50 An OPEN macro issued for a dataset allocated to a printer did not have output specified as an open option. For fixed length records, the BLKSIZE was not a multiple of the LRECL.

S013 - CC - SETPRT PROCESSING FAILED TO SET UP THE DEVICE DURING AN OPEN FOR THE IBM 3800 PRINTING SUBSYSTEM. SA0A Inactive program overlaps overlaps free area; area to be released overlaps a free area. U0101 FDR - disk I/O Error.

THE RECORD OR BLOCK LENGTH PLUS THE KEY LENGTH AND REQUIRED OVERHEAD IS GREATER THAN THE DASD TRACK CAPACITY.

In the abnormal termination dump, the TCB field TCBEXCPD (at offset C0) points to the EXCP problem determination area. when attempting to free all of the storage in a subpool. The volume serial numbers were specified in wrong sequence. Solution 1.

S002-10 An invalid record was encountered on a PUT or WRITE operation. See message TEC025I. Hex offset 54 contains the contents of the request queue element, if allocated, for the I/O request being processed. Mainly SOC7 abend occurs due to invalid digit / sign present at last byte of comp-3 value.

Possible causes: 1. S906 IMS use count limit error. S0CE Significance exception a floating point addition or subtraction results in an all zero fraction note -this is masked in FORTRAN. The specified subpool could not be found.

See message TCS019I. 24An authorized caller attempted to load a module that was not marked as RENT and which was previously loaded by an unauthorized requester. QSAM FILE STATUS 90 Check the DD statement and the SELECT. Attempting to divide by 0 and not using ON SIZE ERROR Solution: 1. S214-04 An I/O error occurred reading a user label on magnetic tape.

Verify that the correct data set and volume will be accessed. S213 - 68 - AN OPEN FOR A PDSE WAS ISSUED WITH RECFM=FB AND LRECL=0. SORTIN JCL gave wrong block size for a variable record. File system input or output error.

S013-8C An OPEN macro was issued for a direct organization dataset (BDAM) but the DCBRECFM parameter was not specific. S001 Input record described incorrectly, length error, tried to read after encountering end-of-file, RECFM V is incompatible with TRTCH ET, tried to write on an input file, read into a table THE TWO LOW-ORDER BYTES OF REGISTER-15 CONTAIN A HEXIDECIMAL REASON CODE. 0000--A HALT NET,CANCEL COMMAND HAS BEEN PROCESSED. 10F1--THE ACF/VTAM STAE RETRY ROUTINE ISSUED AN ABEND 0A9 IN ORDER TO GIVE A multi-volume physical sequential dataset was being written on a direct access device all space was filled on a volume and an attempt was made to obtain space on the next

Resubmit the job specifying a different volume or device. S013-40 A sequential or direct dataset was opened for input, but the buffer control block address was 0.