Home > Ibm Error > Abend S222 U0000

Abend S222 U0000

Contents

Problem 2: After issuing message IGD0221I, SMS subsystem initialization routine IGDSSI00 gets control. AN AUTHORIZED PROGRAM REQUESTED VIRTUAL STORAGE THAT REQUIRES MORE REAL STORAGE THAN IS AVAILABLE. ***IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE*** ***S104 OPERAND FOR MORE SPECIFIC U1026 - COBOL sort failed. APAR Information APAR numberPK93851 Reported component nameWMQ Z/OS V6 Reported component ID5655L8200 Reported release000 StatusCLOSED UR1 PENoPE HIPERNoHIPER Special AttentionNoSpecatt Submitted date2009-08-13 Closed date2009-11-30 Last modified date2009-11-30 APAR is sysrouted FROM

THE RECORD OR BLOCK LENGTH PLUS THE KEY LENGTH AND REQUIRED OVERHEAD IS GREATER THAN THE DASD TRACK CAPACITY. If you would prefer to download this information as an Adobe« Portable Document File, use this link: http://www.jaymoseley.com/hercules/downloads/pdf/sabends.pdf. S0CB - DECIMAL DIVIDE EXCEPTION A QUOTIENT EXCEEDS THE SPECIFIED DATA FIELD SIZE. S04B - AN INVALID OPERATION CODE WAS PASSED TO A TSO LINKAGE ASSIST ROUTINE (LAR). ***IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE*** ***S04B OPERAND FOR MORE

Abend S222 U0000

And we have to put all these records int 1 output file. S171 - 16 - THE INPUT VSL OR ECB FAILED TO PASS THE PAGE SERVICES INTERFACE VALIDITY CHECK. THE SYSTEM DETERMINED THAT A BUFFER POOL EXISTED FOR THIS DATASET AND MADE THE APPROPIATE TEST SHOWN BELOW WITH UNSATISFACTORY RESULTS: - IF THE DATA WAS TO BE SENT DIRECTLY TO S10D - JOBSTEP TASK ABENDED WHEN A SUBTASK THAT IS ALSO A JOBSTEP TASK IS IN STEP-MUST-COMPLETE STATUS.

  1. THE PROGRAM RUNNING AT THE TIME THE OPERATOR PRESSED THE RESTART BUTTON WAS SENT THROUGH ABEND PROCESSING BECAUSE THE OPERATOR DETERMINED IT WAS IN A NONCANCELABLE LOOP OR WAIT STATE.
  2. S001 - 02 - AN ERROR WAS ENCOUNTERED WHILE ATTEMPTING TO CLOSE THE DATASET.
  3. A WRITE MACRO WAS ISSUED CAUSING A SECONDARY EXTENT TO BE OBTAINED.

S002 - 9C - INCORRECT UPDATE WRITE DETECTED. S122 - EITHER THE OPERATOR OR THE JOB ENTRY SUBSYSTEM CANCELLED THE JOB, REQUESTING A DUMP. In the IBM supplied PPT, SMS is marked as a System Task. User Abends In Mainframe S002 - 34 - A READ MACRO WAS ISSUED FOR AN OUTPUT-ONLY DASD DATA SET.

START PSB FROM THE REGION IN WHICH YOU ARE RUNNING YOU ARE RUNNING COMMAND - /start PGM NOTE - Before issuing command , please check PSB is running or not S0B0 - 0C - ATTEMPTING TO READ A BLOCK NOT YET WRITTEN. THE BLOCK WILL NOT FIT ON THE AMOUNT OF SPACE ALLOCATED FOR THE SECONDARY EXTENT. http://www.ibmmainframeforum.com/abends-sql-codes/abend-s222-t9552.html The second column contains a reason code.

S0C7 - DATA EXCEPTION - DECIMAL DATA IS INCORRECT OR IMPROPERLY OVERLAPPED OR NOT VALIDLY INITIALIZED. --POSSIBLE CAUSE-- SUBSCRIPT ERROR, REFERENCED BEYOND TABLE COBOL - WORKING STORAGE NOT INITIALIZED - BAD S222 Charge S003 - THE ERROR OCCURED DURING END-OF-BLOCK PROCESSING USING EITHER BSAM OR QSAM. JCL to create members using Flat File using IEBUPDTE PACK ON/OFF AbendsS0C7 Abend S222 Abend S322 Abend S0C4 Abend S822 Abend File Status ISREDIT Errors Sql Codes What is SQL CODE S047 - AN UNAUTHORIZED PROGRAM REQUESTED A RESTRICTED SVC.

How To Resolve S322 Abend In Jcl

The submitting customer did not required a PTF at MQ Version 6. S002 - 54 - DEBCHK FAILURE DURING PDSE PROCESSING. Abend S222 U0000 S002 - 50 - SERIALIZATION OF AN INTERNAL SAM CONTROL BLOCK (SACB) USED FOPR PROCESSING HAS BEEN VIOLATED. S522 Abend S0B0 - AN UNCORRECTABLE ERROR WAS DETECTED BY THE SWA MANAGER. ***IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE*** ***S0B0 OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND

Is This Answer Correct ? 0 Yes 2 No
Answer / simha we use disp=mod in jcl .how handle this in cobol program Is This Answer Correct ? 0 Yes S013 - 38 - AN OPEN MACRO WAS ISSUED FOR A SEQUENTIAL DATASET ON A DIRECT ACCESS DEVICE WITH TRACK OVERFLOW, BUT THE BUFFER CONTROL BLOCK ADDRESS WAS ZERO. S10E - SPIE MACRO ERROR. S30A - 14 - PRIVATE STORAGE IS NOT IN THE SUBPOOL SPECIFIED. Unsuccessful Sort 222

S137 - 10 - AN I/O ERROR OCCURRED WHILE POSITIONING A MAGNETIC TAPE AT THE END OF THE DATASET. S0A9 - EITHER A HALT NET,CANCEL COMMAND WAS ENTERED OR AN ERROR OCCURRED DURING EXECUTION OF A VTAM MODULE. If we are using select statement, sql error code 100 represents record not found If we are using cursor , in that situation, sql error code 100 represents end of records S029 - AN INVALID VIO REQUEST WAS DETECTED BY THE PAGE OPERATIONS STARTER ROUTINE OF ASM.

S002 - 6C - UNABLE TO CREATE A PDSE MEMBER. Mainframe Abend Codes S314 - I/O ERROR IN READING DSCB ***IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE*** ***S314 OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND O(S314-RC)** --POSSIBLE CAUSE-- SORTIN S0F8 - 14 - THE SVC ISSUER HAD AN ENABLED UNLOCKED TASK MODE FRR.

ACCESS OF A PDSE BY EXCP IS NOT SUPPORTED.

S013 - 50 - AN OPEN MACRO ISSUED FOR A DATASET ALLOCATED TO A PRINTER DID NOT HAVE OUTPUT SPECIFIED AS AN OPEN OPTION. S005 - 08 - THE RBL TYPE OF READ WAS NOT USED FOR THE 3886. During SYSEVENT INTATT processing, the address space is classified again and since the System Task attribute was specified, it will default into service class SYSSTC. Ief450i AEY9 - Invalid EXEC CICS command issued AE** - Most of the abends starts with AE, occures because they are not handled in the cics program.

Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility Google Gruplar─▒ Tart─▒┼čma Forumlar─▒'n─▒ kullanmak i├žin l├╝tfen taray─▒c─▒ ayarlar─▒n─▒zda JavaScript'i etkinle┼čtirin ve sonra bu The value of x will vary depending on the way the job was cancelled. THE AUTHORIZED ROUTINE REQUESTED A MODULE WHICH COULD NOT BE FOUND ON AN AUTHORIZED LIBRARY, BUT A COPY OF THE MODULE MAY HAVE BEEN FOUND ON A NONAUTHORIZED LIBRARY. ***IF THE S106 - 10 - THE CONTROL PROGRAM DETECTED A RELOCATION ERROR IN THE LOAD MODULE.

What does TIME=1440 mean ? 6 Answers TCS, Accenture, A STEP has more than 1 file as INPUT. if it is 35 then open that file for output file. Community Help: S222 Error Code Share your own experience View front page This is a common error message that can occur on mainframe computers. S016 - AN ERROR OCCURRED IN SAM SIO/PAGE FIX OR DASD END-OF-BLOCK MODULES BECAUSE OF ONE OF THE FOLLOWING: - THE DASD END-OF-BLOCK MODULES ISSUED AN EXCPVR SVC REQUEST ON BEHALF

S10A - GETMAIN ERROR. S113 - 30 - INVALID JCL DISPOSITION DETECTED FOR VSAM OPENED WITH A DCB. use following command to stop command /stop PGB ------------ status codes ------------ GE - End Of Segment AC - Invalid SSA * Invalid Segment name specified in SSA * The